Quality assurance reviews during May 2007 at USGS NWQL detected an error by which the identifications of Acetyl-hexamethyl-tetrahydronaphthalene (AHTN) and Hexahydrohexamethylcyclopentabenzopyran (HHCB) were reversed. This error affected data published in this report. The results in this revised publication reflect correct data reporting for these two compounds.

For more information on this issue see the National Water Quality Laboratory Technical Memorandum 2007.03 at http://nwql.usgs.gov/Public/tech_memos/nwql.2007-03.pdf.

A method for the determination of 67 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals in wastewater on aquatic organisms. This method also may be useful for evaluating the impact of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are an indicator of wastewater or that have been chosen on the basis of their endocrine-disrupting potential or toxicity. These compounds include the alkylphenol ethoxylate nonionic surfactants and their degradates, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclicaromatic hydrocarbons, and high-use domestic pesticides.

Water samples are filtered to remove suspended particulate matter and then are extracted by vacuum through disposable solid-phase cartridges that contain polystyrene-divinylbenzene resin. Cartridges are dried with nitrogen gas, and then sorbed compounds are eluted with dichloromethane-diethyl ether (4:1) and determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 4 micrograms per liter averaged 74 percent 7 percent relative standard deviation for all method compounds. Initial method detection limits for single-component compounds (excluding hormones and sterols) averaged 0.15 microgram per liter. Samples are preserved by filtration, the addition of 60 grams NaCl, and storage at 4 degrees Celsius. The laboratory has established a sample-holding time (prior to sample extraction) of 14 days from the date of sample collection until a statistically accepted method can be used to determine the effectiveness of these sample-preservation procedures.

This report is available on the USGS Publishing Network.

VIEW the report. (pdf)


Adobe ® Portable Document Files (pdfs), Microsoft Powerpoint ® Files and Other Sites Open in a New Window

NELAC logo TNI logo NWQL logo

Accessibility FOIA Privacy Policies and Notices

Take Pride in America logo USA.gov logo U.S. Department of the Interior | U.S. Geological Survey
URL: http://nwql.usgs.gov/rpt.shtml
Page Contact Information: NWQL LabHelp
Page Last Modified: Sunday, 16-Apr-2017 19:55:12 MDT